Results 1 - 20 de 54
Filter
1.
Annals of Clinical Microbiology ; : 55-60, 2021.
Article in English | WPRIM | ID: wpr-896716

ABSTRACT

Healthcare workers (HCWs) may be at high risk for exposure to the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) because of their frequent contact with patients or the direct handling of respiratory samples. We investigated the seroprevalence of SARS-CoV-2 IgG in HCWs in Seoul compared to those in coronavirus disease (COVID-19) patients and community-based individuals to evaluate the antibody response. A total of 358 samples from 348 individuals (155 HCWs, 7 COVID-19 patients, and 186 community-based individuals) were collected from April to November 2020. SARS-CoV-2 IgG was detected in 1 of 155 HCWs (1 of 46 HCWs with direct contact), 7 of 7 COVID-19 patients, and none of the 186 communitybased individuals (95% CI: 0.6%, 0.1 - 3.6%; 100%, 64.5 - 100%; 0.0%, 0.0 - 2.0%, respectively).The single HCW with a positive result showed 2.32 signal-to-cutoff (S/C) and 2.31 S/C at a 3-week interval. Therefore, it was assumed to be a false positive due to autoantibody or medication. The positive samples from 7 patients had a median of 3.79 S/C (range 1.72 - 6.54). The seroprevalence of SARS-CoV-2 IgG in HCWs was very low. The current infection control standard seems to be effective in protecting HCWs from COVID-19.

2.
Annals of Laboratory Medicine ; : 268-276, 2021.
Article in English | WPRIM | ID: wpr-874190

ABSTRACT

Background@#Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) is increasingly used for immunosuppressive drug tests. However, most LC-MS/MS tests are laboratory-developed and their agreement is unknown in different Korean laboratories.This interlaboratory comparison study evaluated test reproducibility and identified potential error sources. @*Methods@#Test samples containing three concentrations of tacrolimus, sirolimus, everolimus, cyclosporine, and mycophenolic acid were prepared by pooling surplus samples from patients undergoing routine therapeutic drug monitoring and tested in duplicate in the participating 10 clinical laboratories. Reconstitution and storage experiments were conducted for the commonly used commercial calibrator set. The robust estimators of reproducibility parameters were calculated. Spearman’s rank correlation coefficient (rho, ρ) was used to evaluate the correlation between drugs. Multiple linear regression was used to determine whether the experimental conditions alter the calibration curves. @*Results@#The reproducibility coefficient of variation exceeded 10% only for sirolimus concentrations 1 and 2 (10.8% and 12.5%, respectively) and everolimus concentrations 1 and 2 (12.3% and 11.4%, respectively). The percent difference values showed weak correlations between sirolimus and everolimus (ρ = 0.334, P = 0.175). The everolimus calibration curve slope was significantly altered after reconstitution following prolonged 5°C storage (P = 0.015 for 14 days; P = 0.025 for 28 days); the expected differences at 6 ng/mL were 0.598% for 14 days and 0.384% for 28 days. @*Conclusions@#LC-MS/MS test reproducibility for immunosuppressive drugs seems to be good in the Korean clinical laboratories. Continuous efforts are required to achieve test standardization and harmonization, especially for sirolimus and everolimus.

3.
Annals of Laboratory Medicine ; : 372-379, 2021.
Article in English | WPRIM | ID: wpr-874154

ABSTRACT

Background@#Accurate serum creatinine (Cr) concentration measurement is essential for evaluating kidney function. In 2011, the Korean Association of External Quality Assessment Service (KEQAS) launched an accuracy-based Cr proficiency testing (ABCr PT) survey. We analyzed long-term data of the KEQAS ABCr PT survey collected between 2011 and 2019 to assess recent trends in Cr assays in Korea. @*Methods@#The ABCr PT survey including three commutable fresh-frozen serum samples was performed twice a year. The target Cr concentration was assigned using isotope-dilution mass spectrometry. We analyzed data obtained from the participating laboratories, calculated the yearly bias, and evaluated bias trends for the major reagents and instruments. Outliers were excluded from all analysis. @*Results@#The mean percentage bias based on the total data of all participating laboratories was 10.8% in the 2011-A survey and 0.2% in 2019-B survey. Bias for the major reagents and instruments differed depending on the manufacturer. Enzymatic assays generally showed desirable bias ranging from –3.9% to 3.2% at all Cr concentrations and lower interlaboratory variability than non-enzymatic assays (enzymatic vs. non-enzymatic, 3.3%– 7.2% vs. 6.3%–9.1%). @*Conclusions@#Although the mean percentage bias of Cr assays tends to decrease over time, it is necessary to continuously strive to improve Cr assay accuracy, especially at low concentrations.

4.
Annals of Laboratory Medicine ; : 60-67, 2021.
Article in English | WPRIM | ID: wpr-874136

ABSTRACT

Background@#Neutrophil gelatinase-associated lipocalin (NGAL) is a useful biomarker for acute kidney injury (AKI) prediction. However, studies on whether using both plasma NGAL (PNGAL) and urine NGAL (UNGAL) can improve AKI prediction are limited. We investigated the best approach to predict AKI in high-risk patients when using PNGAL and UNGAL together. @*Methods@#We enrolled 151 AKI suspected patients with one or more AKI risk factors. We assessed the diagnostic performance of PNGAL and UNGAL for predicting AKI according to chronic kidney disease (CKD) status by determining the areas under the receiver operating curve (AuROC). Independent predictors of AKI were assessed using univariate and multivariate logistic regression analyses. @*Results@#In the multivariate logistic regression analysis for all patients (N = 151), Model 2 and 3, including PNGAL (P = 0.012) with initial serum creatinine (S-Cr), showed a better AKI prediction power (R2 = 0.435, both) than Model 0, including S-Cr only (R2 = 0.390). In the non-CKD group (N = 135), the AuROC of PNGAL for AKI prediction was larger than that of UNGAL (0.79 vs 0.66, P = 0.010), whereas in the CKD group (N = 16), the opposite was true (0.94 vs 0.76, P = 0.049). @*Conclusions@#PNGAL may serve as a useful biomarker for AKI prediction in high-risk patients. However, UNGAL predicted AKI better than PNGAL in CKD patients. Our findings provide guidance for selecting appropriate specimens for NGAL testing according to the presence of CKD in AKI high-risk patients.

5.
Annals of Clinical Microbiology ; : 55-60, 2021.
Article in English | WPRIM | ID: wpr-889012

ABSTRACT

Healthcare workers (HCWs) may be at high risk for exposure to the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) because of their frequent contact with patients or the direct handling of respiratory samples. We investigated the seroprevalence of SARS-CoV-2 IgG in HCWs in Seoul compared to those in coronavirus disease (COVID-19) patients and community-based individuals to evaluate the antibody response. A total of 358 samples from 348 individuals (155 HCWs, 7 COVID-19 patients, and 186 community-based individuals) were collected from April to November 2020. SARS-CoV-2 IgG was detected in 1 of 155 HCWs (1 of 46 HCWs with direct contact), 7 of 7 COVID-19 patients, and none of the 186 communitybased individuals (95% CI: 0.6%, 0.1 - 3.6%; 100%, 64.5 - 100%; 0.0%, 0.0 - 2.0%, respectively).The single HCW with a positive result showed 2.32 signal-to-cutoff (S/C) and 2.31 S/C at a 3-week interval. Therefore, it was assumed to be a false positive due to autoantibody or medication. The positive samples from 7 patients had a median of 3.79 S/C (range 1.72 - 6.54). The seroprevalence of SARS-CoV-2 IgG in HCWs was very low. The current infection control standard seems to be effective in protecting HCWs from COVID-19.

6.
Laboratory Medicine Online ; : 250-254, 2020.
Article | WPRIM | ID: wpr-836916

ABSTRACT

Mucormycosis is a fungal infection, which is difficult to treat due to its rapid dissemination and low susceptibility to anti-fungal agents. Peritonitis preceded by gastrointestinal mucormycosis is very rare, and only a few cases have been reported. We present a case of peritonitis and disseminated mucormycosis caused by Mucor circinelloides in an immunocompromised patient. A 59-year-old man, diagnosed with nodal marginal zone B-cell lymphoma, was diagnosed with liver failure due to severe septic shock. A white, woolly cotton-like growth, which was consistent with that of Mucor species, was isolated from ascites and sputum specimens. Targeted DNA sequencing confirmed the isolate as M. circinelloides with 100% identity. Despite anti-fungal treatment, the patient died after four days. This is a rare case of peritonitis and disseminated mucormycosis that was probably preceded by gastrointestinal mucormycosis caused by M. circinelloides, as determined by molecular methods. Accurate and rapid identification of mold using molecular methods might be necessary for early treatment in critical cases, and more cases should be clinically evaluated further.

7.
Journal of the Korean Medical Association ; : 493-503, 2020.
Article | WPRIM | ID: wpr-834739

ABSTRACT

A new diagnosis-related group (DRG) based payment system has been implemented in most public hospitals in Korea. We investigated the effects of the new DRG system and its incentive policy on the utilization rate of diagnostic laboratory tests. Three groups were categorized; 36 hospitals under the new DRG system (participant group), 72 hospitals (control-1) matching with 36 participants according to the number of beds, and 42 tertiary hospitals (control-2). The patients of acute myocardial infarction, cerebral infarction, type 2 diabetes mellitus, and gonarthrosis receiving total arthroplasty were included. We analyzed the mean length of stay and the number of diagnostic laboratory tests conducted during hospitalization of the three groups according to the new DRG system and the incentive policy rates under the new DRG system. Before participating in the new DRG system, the number of diagnostic laboratory tests in the participant group was less than that in the two control groups for all four diseases. However, although the participant group’s length of stay decreased under the new DRG system, the number of diagnostic laboratory tests increased as the maximum incentive policy rate increased. The increment of the number of diagnostic laboratory tests was prominent in the period of a maximum of 35% incentive policy rates. Finally, the number of diagnostic laboratory tests of the participant group was similar to or exceeded that of the control-2 group. The new DRG system’s incentive policy rates played a driving force on the increased utilization rate of the diagnostic laboratory test. For preparing in advance for the change in incentive policy rates, monitoring and guidelines for the utilization of diagnostic laboratory tests are necessary.

8.
Annals of Laboratory Medicine ; : 474-480, 2020.
Article | WPRIM | ID: wpr-830419

ABSTRACT

Background@#A rise and/or fall in cardiac troponin value with at least one value above the 99th percentile upper reference limit is essential for acute myocardial infarction (AMI) diagnosis. We evaluated the clinical usefulness of serial high-sensitivity cardiac troponin I (hs-cTnI) measurements in AMI diagnosis, in terms of the predictability of absolute and relative changes. @*Methods@#For this retrospective, forward observational study, we enrolled 281 patients older than 18 years who presented with chest pain at the emergency department (ED) between August 2015 and December 2016. The patients were grouped as AMI and nonAMI, and 73 (26%) were diagnosed as having AMI. Hs-cTnI (Abbott Diagnostics, Abbott Park, IL, USA) was measured at presentation and 3 hours later. We assessed the diagnostic performance of the absolute and relative changes in hs-cTnI. @*Results@#The cut-off values to predict AMI were 16.2 ng/L and 42.1% for the absolute and relative hs-cTnI changes, respectively. The area under the curve of hs-cTnI for AMI diagnosis was larger for absolute changes than for relative changes [0.96 (95% confidence interval [CI], 0.92–0.98) vs 0.89 (95% CI, 0.85–0.93)] (P = 0.014). @*Conclusions@#The absolute hs-cTnI change at 3 hours after presentation was superior to the relative change, and a rise and/or fall in hs-cTnI of > 16.2 ng/L at 3 hours after presentation was useful to identify AMI in patients presenting at the ED.

9.
Annals of Laboratory Medicine ; : 72-75, 2020.
Article in English | WPRIM | ID: wpr-762451

ABSTRACT

Accurate detection of BCR-ABL fusion transcripts at and below molecular response (MR) 4 (0.01% International Scale [IS]) is required for disease monitoring in patients with chronic myeloid leukemia (CML). We evaluated the analytical performance of the QXDx BCR-ABL %IS (Bio-Rad, Hercules, CA, USA) droplet digital PCR (ddPCR) assay, which is the first commercially available ddPCR-based in vitro diagnostics product. In precision analysis, the %CV was 9.3% and 3.0%, with mean values of 0.031% IS and 9.4% IS, respectively. The assay was linear in the first order, ranging from 0.032% IS to 20% IS. The manufacturer-claimed limit of blank, limit of detection, and limit of quantification were verified successfully. There was a very strong correlation between the results of the QXDx BCR-ABL %IS ddPCR assay and the ipsogen BCR-ABL1 Mbcr IS-MMR (Qiagen, Hilden, Germany) real-time quantitative PCR assay (r=0.996). In conclusion, the QXDx BCR-ABL %IS ddPCR assay can provide reliable results for CML patients.


Subject(s)
Humans , In Vitro Techniques , Leukemia, Myelogenous, Chronic, BCR-ABL Positive , Limit of Detection , Polymerase Chain Reaction
11.
Laboratory Medicine Online ; : 161-165, 2019.
Article in Korean | WPRIM | ID: wpr-760500

ABSTRACT

The Clinical Mass Spectrometry Research Committee (CMSRC), in affiliation with the Korean Society of Clinical Chemistry (KSCC), conducted a questionnaire survey on opinions about the general status of clinical mass spectrometric analysis in Korea. As a result, we understand that this field has passed through the introductory stage and is settled as a field of clinical laboratory testing in Korea, with the number of new laboratories performing mass spectrometric analysis being low. In spite of the many difficulties in introducing and operating clinical mass spectrometric analysis, there is a strong interest in this field, and even though further expansion is expected, there are still many issues to be resolved. In the future, it will be necessary to make concrete and thorough efforts to further develop the laboratory tests using clinical mass spectrometric analysis in Korea, centering on the CMSRC affiliated with the KSCC.


Subject(s)
Chemistry, Clinical , Korea , Mass Spectrometry
12.
Journal of Laboratory Medicine and Quality Assurance ; : 121-129, 2019.
Article in Korean | WPRIM | ID: wpr-765650

ABSTRACT

The accuracy-based lipid (ABL) proficiency testing (PT) program was started in 2016 by the Korean External Quality Assessment Service to minimize the matrix effect. We analyzed 3 years of the program. We made or purchased six kinds of commutable frozen sera based on the Clinical and Laboratory Standards Institute 37A guideline and distributed it in two rounds per year from 2016 to 2018. We obtained reference values for levels of total cholesterol (TC), high-density lipoprotein cholesterol (HDLC), low-density lipoprotein cholesterol (LDLC), total glycerides, and triglycerides in each fresh frozen pool at the reference-measurement laboratories. We evaluated the average percent bias of the participating laboratories based on the National Cholesterol Education Program (NCEP) bias limit. The number of participating laboratories evaluating TC, HDLC, LDLC, total glycerides, and triglycerides increased from 164 to 223, 163 to 223, 158 to 214, 98 to 139, and 61 to 82, respectively. The average percent bias of all participating laboratories for TC, HDLC, LDLC, total glycerides, and triglycerides was +0.14%, −0.54%, +2.9%, −1.08%, and −1.32%, respectively. The average percent bias exceeded the NCEP bias limit only once or twice for TC, HDLC, and total glycerides but frequently for LDLC (eight out of 18 pools). The manufacturer-specific bias estimation report seemed useful for traceability. Although the average percent bias of participating laboratories for TC, HDLC, LDLC, total glycerides, and triglycerides was mostly within the bias limit provided by NCEP, cases of bias limit exceeding the NCEP bias limit occurred occasionally, especially for LDLC during the 3 years of the ABL PT program in Korea, suggesting that ABL PT can be used to keep maintaining traceability.


Subject(s)
Bias , Cholesterol , Education , Glycerides , Korea , Laboratory Proficiency Testing , Lipoproteins , Reference Values , Triglycerides
13.
Journal of Laboratory Medicine and Quality Assurance ; : 13-23, 2019.
Article in Korean | WPRIM | ID: wpr-741142

ABSTRACT

BACKGROUND: Standardization of creatinine assay is consistently performed and much effort has been put into improving the accuracy of the results. We aimed to analyze the results of accuracy-based proficiency testing of creatinine assays performed by the Korea Association of External Quality Assessment Service from 2011 to 2017 to assess the current state of creatinine assays in Korea. METHODS: From 2011 to 2017, the accuracy-based proficiency testing of creatinine was performed twice a year. We analyzed the results obtained from the participating laboratories and calculated the year-wise bias. The acceptable limit of bias was as follows: ±11.4% for creatinine concentration >1.0 mg/dL, and 0.114 mg/dL for creatinine concentration ≤1.0 mg/dL. The trend of bias with the major instruments and reagent manufacturers were analyzed. RESULTS: The number of participating laboratories was 54 in 2011, which gradually increased to 146–178 after 2015. For each of the three samples used in the survey, the percentage of laboratories whose biases in the results were within the acceptable limits was 33.3% for the first time in 2011, which gradually increased to 74.7%–85.0% after 2014. The mean biases in all the results of the participating laboratories were 11.1% in 2011 (1st trial) and 2.4% in 2017 (2nd trial). The biases in the results with the major instruments and reagents differed according to the manufacturers. CONCLUSIONS: The mean bias in the results obtained from the participating laboratories in the accuracy-based proficiency testing of creatinine surveys showed a decreasing trend.


Subject(s)
Bias , Creatinine , Indicators and Reagents , Korea
14.
The Korean Journal of Internal Medicine ; : 893-901, 2018.
Article in English | WPRIM | ID: wpr-716633

ABSTRACT

BACKGROUND/AIMS: In countries with a higher risk of gastric atrophic gastritis, noninvasive tests are helpful for a more reliable diagnosis of Helicobacter pylori infection. The aim of this study was to evaluate the characteristics of seropositive subjects according to their stool H. pylori antigen test, serum pepsinogen (PG) assay, and endoscopic findings. METHODS: Consecutive subjects who visited Konkuk University Medical Center for upper gastrointestinal endoscopy for a regular check-up were included in a prospective setting if the serum anti-H. pylori immunoglobulin G assay was positive. A H. pylori antigen stool test was measured using a stool H. pylori antigen enzyme-linked immunosorbent assay kit on the same day as a serum PG assay and endoscopy. RESULTS: Of 318 seropositive subjects, 256 (80.5%) showed positive stool test findings. Subjects with a negative stool test result showed lower serum PG I (p < 0.001) and PG II (p < 0.001) levels and higher PG I/II ratio (p < 0.001) than those with a positive stool test. Chronic atrophic gastritis was more common in the positive stool test group than the negative stool test group on endoscopic finding (p = 0.009). A higher serum PG I level (p = 0.001) and a lower serum PG I/II ratio (p = 0.001) were independent risk factors for the presence of H. pylori antigen in stool. CONCLUSIONS: A high serum PG level denotes an ongoing current H. pylori infection with positive stool H. pylori antigen test findings. Seropositive subjects with increased gastric secreting ability tend to have H. pylori in their fecal material as reflected by a positive stool H. pylori antigen test finding.


Subject(s)
Academic Medical Centers , Diagnosis , Endoscopy , Endoscopy, Gastrointestinal , Enzyme-Linked Immunosorbent Assay , Gastritis, Atrophic , Helicobacter pylori , Helicobacter , Immunoglobulin G , Pepsinogen A , Prospective Studies , Risk Factors
15.
Annals of Laboratory Medicine ; : 331-337, 2018.
Article in English | WPRIM | ID: wpr-715661

ABSTRACT

BACKGROUND: Liver biopsies have been partially replaced by noninvasive methods for assessing liver fibrosis. We explored the usefulness of four novel biomarkers, enhanced liver fibrosis (ELF), glycosylation isomer of Mac-2 binding protein (M2BPGi), galectin-3, and soluble suppression of tumorigenicity 2 (sST2), in association with liver fibrosis. METHODS: ELF, M2BPGi, galectin-3, and sST2 were assayed in 173 patients with chronic liver diseases. The results were analyzed according to fibrosis grade (F0/1, F2, and F3/4) by transient elastography (TE). RESULTS: ELF, M2BPGi, galectin-3, and sST2 values differed significantly according to TE grade; ELF and M2BPGi values were higher in F2 and F3/4 than in F0/1 (P≤0.001, all), sST2 values were higher in F3/4 than in F0/1 and F2 (P < 0.05), and galectin-3 values were higher in F3/4 than in F0/1 (P=0.0036). ELF and M2BPGi showed good TE fibrosis detection performance (area under the curves [AUC], 0.841 and 0.833 for ≥F2; and 0.837 and 0.808 for ≥F3). The sensitivity and specificity for predicting TE grade F≥2 were 84.1% and 76.7% for ELF and 63.6% and 91.5% for M2BPGi. CONCLUSIONS: This is the first study to compare the liver fibrosis assessment of four novel biomarkers: ELF, M2BPGi, galectin-3, and sST2. The biomarkers varied significantly according to TE grade, and each biomarker showed a different trend. ELF and M2BPGi seem to have comparable good performance for detecting liver fibrosis.


Subject(s)
Humans , Biomarkers , Biopsy , Carrier Proteins , Elasticity Imaging Techniques , Fibrosis , Galectin 3 , Glycosylation , Liver Cirrhosis , Liver Diseases , Liver , Sensitivity and Specificity
16.
Laboratory Medicine Online ; : 111-119, 2017.
Article in English | WPRIM | ID: wpr-110642

ABSTRACT

BACKGROUND: JEOL BioMajesty JCA-BM6010/C (JCA-BM6010/C, JEOL Ltd., Japan) is a recently developed ultra-compact automated clinical chemistry analyzer with a throughput of 1,200 tests per hour. Here, we present the first performance evaluation of JCA-BM6010/C. METHODS: We evaluated the precision, linearity, correlation, accuracy, and carryover of 11 analytes (ALP, ALT, AST, calcium, creatinine, GGT, glucose, LDH, total bilirubin, total protein, and uric acid) using the JEOL closed reagent (JEOL Ltd.) according to the guidelines of the Clinical Laboratory Standards Institute. Linearity was further evaluated for ALT, AST, and GGT using open reagents by Sekisui (Japan). The performance of JCA-BM6010/C was compared to that of the Roche-Hitachi Cobas 8000 c702 chemistry autoanalyzer (Cobas 8000, Roche Diagnostics, Switzerland). Its performance using open reagents from Denka Seiken (Japan), Roche, and Sekisui was also evaluated. RESULTS: The total coefficients of variation (CV) for all analytes were 1.0–2.7%. Linearity was observed for all analytes over the entire tested analytical range (R²≥0.99). The results of JCA-BM6010/C strongly correlated (r≥0.988) with those of Cobas 8000 for all evaluated analytes except LDH (r=0.963), as well as for all open reagents. Recovery rates for creatinine, glucose, calcium, and uric acid were 96.6–101.5% and 98.7–109.3% with the JEOL exclusive and open reagents, respectively. Sample carryover was less than 0.34%. CONCLUSIONS: JCA-BM6010/C showed acceptable performance in the precision, linearity, correlation, accuracy, and sample carryover analyses and in the method comparison. Therefore, it could be a useful routine laboratory medical analyzer.


Subject(s)
Bilirubin , Calcium , Chemistry , Chemistry, Clinical , Creatinine , Glucose , Indicators and Reagents , Methods , Uric Acid
17.
Laboratory Medicine Online ; : 176-181, 2017.
Article in Korean | WPRIM | ID: wpr-51172

ABSTRACT

BACKGROUND: Soluble ST2 (sST2) has emerged as a biomarker of heart failure. Previous studies indicated 35 ng/mL of sST2 as the clinically prognostic cut-off value. This study aims to establish reference intervals in a Korean population using an sST2 assay and to evaluate the applicability of the cut-off value. METHODS: From March to May 2014, sST2 levels were assayed in serum samples of 255 cardio-healthy Koreans (128 men and 127 women) using the Presage ST2 ELISA kit (Critical Diagnostics, USA). The reference interval for sST2 was defined using the nonparametric percentile method according to the CLSI EP28-A3c guideline. RESULTS: The median sST2 concentrations were 23.8 ng/mL (interquartile range (IQR), 19.0-28.7), 26.6 ng/mL (IQR, 21.0-30.9), and 21.9 ng/mL (IQR, 17.3-26.5) for the entire cohort, men, and women, respectively. sST2 levels were significantly higher in men than in women (P<0.0001). The 97.5th percentile upper reference limits for sST2 were 43.8 ng/mL, 49.6 ng/mL, and 35.4 ng/mL for the cohort, men, and women, respectively. Gender-specific upper reference limits were similar to limits reported by other studies. CONCLUSIONS: We suggest that gender-specific reference intervals should be used for the Korean population, as application of a single cut-off value of 35 ng/mL may be overcautious of the possibility of false positivity, especially in men.


Subject(s)
Female , Humans , Male , Cohort Studies , Enzyme-Linked Immunosorbent Assay , Heart Failure , Methods
18.
Annals of Laboratory Medicine ; : 1-8, 2017.
Article in English | WPRIM | ID: wpr-72424

ABSTRACT

BACKGROUND: For correct interpretation of the high-density lipoprotein cholesterol (HDL-C) data from the Korea National Health and Nutrition Examination Survey (KNHANES), the values should be comparable to reference values. We aimed to suggest a way to calibrate KNHANES HDL-C data from 2008 to 2015 to the Centers for Disease Control and Prevention (CDC) reference method values. METHODS: We derived three calibration equations based on comparisons between the HDL-C values of the KNHANES laboratory and the CDC reference method values in 2009, 2012, and 2015 using commutable frozen serum samples. The selection of calibration equation for correcting KNHANES HDL-C in each year was determined by the accuracy-based external quality assurance results of the KNHANES laboratory. RESULTS: Significant positive biases of HDL-C values were observed in all years (2.85-9.40%). We created the following calibration equations: standard HDL-C=0.872×[original KNHANES HDL-C]+2.460 for 2008, 2009, and 2010; standard HDL-C=0.952×[original KNHANES HDL-C]+1.096 for 2012, 2013, and 2014; and standard HDL-C=1.01×[original KNHANES HDL-C]-3.172 for 2011 and 2015. We calibrated the biases of KNHANES HDL-C data using the calibration equations. CONCLUSIONS: Since the KNHANES HDL-C values (2008-2015) showed substantial positive biases compared with the CDC reference method values, we suggested using calibration equations to correct KNHANES data from these years. Since the necessity for correcting the biases depends on the characteristics of research topics, each researcher should determine whether to calibrate KNHANES HDL-C data or not for each study.


Subject(s)
Humans , Algorithms , Calibration , Cholesterol, HDL/blood , Nutrition Surveys , Reference Values , Republic of Korea
19.
Annals of Laboratory Medicine ; : 34-38, 2017.
Article in English | WPRIM | ID: wpr-72420

ABSTRACT

BACKGROUND: The associations of vitamin D deficiency with various clinical conditions highlighted the importance of vitamin D testing. Currently, clinicians measure only the total 25-hydroxyvitamin D [25(OH)D] concentration, regardless of its bioavailability. We aimed to determine the effect of vitamin D-binding protein (VDBP) on 25(OH)D bioavailability. METHODS: Serum samples were collected from 60 healthy controls, 50 pregnant women, and 50 patients in intensive care units (ICUs). Total 25(OH)D was quantified by liquid chromatography with tandem mass spectrometry, and VDBP levels were determined by using an ELISA kit (R&D Systems, USA). The bioavailable 25(OH)D levels were calculated by using total 25(OH)D, VDBP, and albumin concentrations. RESULTS: In comparison with healthy controls, the total 25(OH)D concentration was significantly lower in ICU patients (median, 11.65 vs 18.25 ng/mL; P<0.00001), but no significant difference was noted between pregnant women (18.25 ng/mL) and healthy controls. The VDBP level was significantly lower in ICU patients (95.58 vs 167.18 µg/mL, P=0.0002) and higher in pregnant women (225.01 vs 167.18 µg/mL, P=0.008) compared with healthy controls. Nonetheless, the calculated bioavailable 25(OH)D levels of ICU patients and pregnant women were significantly lower than those of healthy controls (1.97 and 1.93 ng/mL vs 2.56 ng/mL; P=0.0073 and 0.0027). CONCLUSIONS: A single marker of the total 25(OH)D level is not sufficient to accurately evaluate vitamin D status, especially in pregnant women. In cases where VDBP concentrations may be altered, VDBP measurements and bioavailable 25(OH)D calculations may help to determine vitamin D status accurately.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Pregnancy , Chromatography, High Pressure Liquid , Enzyme-Linked Immunosorbent Assay , Intensive Care Units , Pregnant Women , Serum Albumin/analysis , Tandem Mass Spectrometry , Vitamin D/blood , Vitamin D-Binding Protein/blood
20.
Annals of Laboratory Medicine ; : 129-136, 2017.
Article in English | WPRIM | ID: wpr-8650

ABSTRACT

BACKGROUND: Cytomegalovirus (CMV) and Epstein-Barr virus (EBV) are increasingly important in immunocompromised patients. Nucleic acid extraction methods could affect the results of viral nucleic acid amplification tests. We compared two automated nucleic acid extraction systems for detecting CMV and EBV using real-time PCR assays. METHODS: One hundred and fifty-three whole blood (WB) samples were tested for CMV detection, and 117 WB samples were tested for EBV detection. Viral nucleic acid was extracted in parallel by using QIAsymphony RGQ and QIAcube (Qiagen GmbH, Germany), and real-time PCR assays for CMV and EBV were performed with a Rotor-Gene Q real-time PCR cycler (Qiagen). Detection rates for CMV and EBV were compared, and agreements between the two systems were analyzed. RESULTS: The detection rate of CMV and EBV differed significantly between the QIAsymphony RGQ and QIAcube systems (CMV, 59.5% [91/153] vs 43.8% [67/153], P=0.0005; EBV, 59.0% [69/117] vs 42.7% [50/117], P=0.0008). The two systems showed moderate agreement for CMV and EBV detection (kappa=0.43 and 0.52, respectively). QIAsymphony RGQ showed a negligible correlation with QIAcube for quantitative EBV detection. QIAcube exhibited EBV PCR inhibition in 23.9% (28/117) of samples. CONCLUSIONS: Automated nucleic acid extraction systems have different performances and significantly affect the detection of viral pathogens. The QIAsymphony RGQ system appears to be superior to the QIAcube system for detecting CMV and EBV. A suitable sample preparation system should be considered for optimized nucleic acid amplification in clinical laboratories.


Subject(s)
Humans , Automation , Cytomegalovirus/genetics , Cytomegalovirus Infections/diagnosis , DNA, Viral/blood , Herpesvirus 4, Human/genetics , Reagent Kits, Diagnostic , Real-Time Polymerase Chain Reaction